A PLC power supply module does not normally supply power to the field devices.

A) True
B) False

Correct Answer

verifed

verified

Which module of the PLC connects directly to field devices such as pilot lights,motor starters,and solenoids?


A) Input
B) Output
C) Power supply
D) Memory

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

Removing the programming device from the PLC will not affect the operation of the user program.

A) True
B) False

Correct Answer

verifed

verified

The main difference between a PLC and relay control system is that:


A) different types of input devices are used.
B) different types of output devices are used.
C) different input and output voltage levels are used.
D) one uses hardwired relay control logic and the other uses programmed instructions.

E) A) and B)
F) B) and D)

Correct Answer

verifed

verified

At the start of the PLC scan the:


A) status of all inputs are read.
B) status of all outputs are updated.
C) program is executed.
D) diagnostics and communications tasks are executed.

E) None of the above
F) A) and C)

Correct Answer

verifed

verified

The programming device:


A) is used to enter the program into the memory of the processor.
B) is commonly a personal computer.
C) can be a hand-held device.
D) All of the above.

E) A) and D)
F) B) and C)

Correct Answer

verifed

verified

Which module of the PLC is responsible for performing logical operations?


A) Processor
B) Input
C) Output
D) Power supply

E) A) and C)
F) A) and B)

Correct Answer

verifed

verified

The instruction set for a particular PLC lists the types of instructions supported.

A) True
B) False

Correct Answer

verifed

verified

Software installed and run on a personal computer can be used to write a PLC program.

A) True
B) False

Correct Answer

verifed

verified

The voltage that would be present between the DC common and terminal 4 with the pushbutton closed would be approximately: The voltage that would be present between the DC common and terminal 4 with the pushbutton closed would be approximately:   A) 0 volts. B) 6 volts. C) 12 volts. D) 24 volts.


A) 0 volts.
B) 6 volts.
C) 12 volts.
D) 24 volts.

E) A) and D)
F) All of the above

Correct Answer

verifed

verified

One disadvantage of modular I/O is its lack of flexibility.

A) True
B) False

Correct Answer

verifed

verified

Unlike personal computers,PLCs are:


A) equipped with input and output modules.
B) equipped with a control programming language.
C) designed for the industrial environment.
D) All of the above.

E) A) and D)
F) A) and C)

Correct Answer

verifed

verified

Block No.3 of the PLC block diagram represents the: Block No.3 of the PLC block diagram represents the:   A) CPU unit. B) programming device. C) input module. D) output module.


A) CPU unit.
B) programming device.
C) input module.
D) output module.

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

The diagram shown is that of a: The diagram shown is that of a:   A) relay schematic. B) ladder logic program. C) input module wiring diagram. D) output module wiring diagram.


A) relay schematic.
B) ladder logic program.
C) input module wiring diagram.
D) output module wiring diagram.

E) A) and D)
F) A) and C)

Correct Answer

verifed

verified

PLCs were originally designed as replacements for:


A) microcomputers.
B) relay control panels.
C) analog controllers.
D) digital controllers.

E) A) and D)
F) A) and C)

Correct Answer

verifed

verified

The number of I/O points does not affect the memory size required for a PLC installation.

A) True
B) False

Correct Answer

verifed

verified

In order to energize the starter coil: In order to energize the starter coil:   A) the pressure switch,and the temperature switch,and the manual pushbutton must be closed. B) the pressure switch,or the temperature switch,or the manual pushbutton must be closed. C) the pressure switch,and the temperature switch,or the manual pushbutton must be closed. D) All of the above.


A) the pressure switch,and the temperature switch,and the manual pushbutton must be closed.
B) the pressure switch,or the temperature switch,or the manual pushbutton must be closed.
C) the pressure switch,and the temperature switch,or the manual pushbutton must be closed.
D) All of the above.

E) A) and D)
F) C) and D)

Correct Answer

verifed

verified

Block No.6 of the PLC block diagram represents the: Block No.6 of the PLC block diagram represents the:   A) processor module. B) power supply module. C) input module. D) output module.


A) processor module.
B) power supply module.
C) input module.
D) output module.

E) All of the above
F) B) and C)

Correct Answer

verifed

verified

I/Os are typical of small PLCs that come in one package with no separate removable units.


A) Fixed
B) Modular
C) Digital
D) Analog

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

Showing 41 - 59 of 59